Specifications
975-0125-02-01 A–3
Main Charger Specifications
All charging specifications are at nominal conditions: ambient temperature of 77
°F (25 °C), 120 VAC, 60 Hz input, unless otherwise specified.
Table A-2
Main Charger Specifications
Charging method • Three-stage charge (Bulk, Absorption, Float)
• Two-stage charge (Bulk, Absorption)
The default charging method is three-stage.
Without a battery temperature
sensor
Three settings with the following temperature
values:
• Cool 50 °F (10 °C)
• Warm 77 °F (25 °C)
• Hot 104 °F (40 °C)
The default value for this setting is Hot, and it can
only be changed by a dealer, factory, or service
center.
With a battery temperature
sensor
The temperature compensation coefficients on a
12 volt battery are as follows:
• Flooded: 27 mV × (25 °C – BTS °C)
• Gel: 27 mV × (25 °C – BTS °C)
• AGM: 21 mV × (25 °C – BTS °C)
Equalization cycle Yes, manual via System Control Panel
Number of independent battery
banks
1
Battery bank size settings 50 – 2000 Ah
Battery type settings Flooded, AGM, Gel, Custom
Power factor corrected charging Yes
AC input voltage 90 – 135 VAC
AC input frequency 60 Hz nominal, 55 – 65 Hz operating range
Minimum battery voltage 3.0 VDC
Maximum DC output voltage 16.0 VDC
Charger efficiency ≥ 85%
Input power factor at full
charge rate
> 0.95
Maximum charge current 100 A