Specifications
975-0125-02-01 A3
Main Charger Specifications
All charging specifications are at nominal conditions: ambient temperature of 77
°F (25 °C), 120 VAC, 60 Hz input, unless otherwise specified.
Table A-2
Main Charger Specifications
Charging method Three-stage charge (Bulk, Absorption, Float)
Two-stage charge (Bulk, Absorption)
The default charging method is three-stage.
Without a battery temperature
sensor
Three settings with the following temperature
values:
Cool 50 °F (10 °C)
Warm 77 °F (25 °C)
Hot 104 °F (40 °C)
The default value for this setting is Hot, and it can
only be changed by a dealer, factory, or service
center.
With a battery temperature
sensor
The temperature compensation coefficients on a
12 volt battery are as follows:
Flooded: 27 mV × (25 °C BTS °C)
Gel: 27 mV × (25 °C BTS °C)
AGM: 21 mV × (25 °C BTS °C)
Equalization cycle Yes, manual via System Control Panel
Number of independent battery
banks
1
Battery bank size settings 50 2000 Ah
Battery type settings Flooded, AGM, Gel, Custom
Power factor corrected charging Yes
AC input voltage 90 135 VAC
AC input frequency 60 Hz nominal, 55 65 Hz operating range
Minimum battery voltage 3.0 VDC
Maximum DC output voltage 16.0 VDC
Charger efficiency 85%
Input power factor at full
charge rate
> 0.95
Maximum charge current 100 A