Xantrex GT5.0-NA Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Adaptadores e conversores de corrente Xantrex GT5.0-NA. Xantrex GT5.0-NA User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Grid Tie Solar Inverter
Xantrex Grid Tie
Solar Inverter
Owner’s Manual
GT5.0-NA
Vista de página 0
1 2 3 4 5 6 ... 83 84

Resumo do Conteúdo

Página 1 - Solar Inverter

Grid Tie Solar InverterXantrex Grid Tie Solar InverterOwner’s ManualGT5.0-NA

Página 2

Safetyviii 975-0320-01-01Location of Safety and Data LabelsThe figure below shows the location of the safety label and the data label with model, seri

Página 3 - Owner’s Manual

975-0320-01-01 ixImportant Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - viiLocation of Safety and Data Labels

Página 4

Contentsx 975-0320-01-014Starting the InverterStartup Procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Página 5 - About This Manual

Contents975-0320-01-01 xiMechanical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–5

Página 7 - Related Information

1IntroductionChapter 1 contains information about the features and functions of the Xantrex Grid Tie Solar Inverter.About the Xantrex Grid Tie Solar I

Página 8

Introduction1–2 975-0320-01-01PV compatibility The GT Inverter is designed to take advantage of solar modules configured as high voltage PV string arr

Página 9 - Important Safety Instructions

About the Xantrex Grid Tie Solar Inverter975-0320-01-01 1–3Front Panel FeaturesWiring/Disconnect BoxThe wiring/disconnect box is standard for all Nort

Página 11 - Contents

2InstallationChapter 2 provides information about installing the GT Inverter. It contains information on determining a suitable location for installat

Página 13 - 975-0320-01-01 xi

Installation2–2 975-0320-01-01Inverter failure due to improper installation will void the inverter warranty. Consider the following when determining w

Página 14

Planning the Installation975-0320-01-01 2–3PV Array Voltage and MPPT RequirementsMPPT operational windowThe MPPT software maximizes the output energy

Página 15 - Introduction

Installation2–4 975-0320-01-01Guidelines for Matching PV Array Size to Xantrex Grid Tie Solar Inverter Input• Consider the expected Voc of the string

Página 16 - WARNING: Shock hazard

Mounting the Inverter975-0320-01-01 2–5Mounting the InverterDimensions and Knockout LocationsThe dimensions of the inverter and the mounting bracket a

Página 17 - Grid Tie Solar Inverter

Installation2–6 975-0320-01-01Installing the Mounting BracketThe mounting bracket is designed to be affixed to the vertical structure or surface to wh

Página 18

Mounting the Inverter975-0320-01-01 2–7Clearance RequirementsFor optimal and safe operation, ensure there is adequate clearance around the inverter. I

Página 19 - Installation

Installation2–8 975-0320-01-01Mounting the Inverter on the BracketPlace the inverter’s mounting hooks over the flanges on the bracket. Ensure the inve

Página 20

3Wiring the InverterChapter 3 provides information about DC and AC wiring, and grounding the GT Inverter and the PV array.This chapter does not provid

Página 21 - CAUTION: Equipment damage

Wiring the Inverter3–2 975-0320-01-01The ground bar accepts wires up to #4 AWG. Torque ground wires as specified in Table 3-1.Figure 3-1Ground Conduct

Página 22 - °C (77 °F). Ensure that the V

Grounding Requirements975-0320-01-01 3–3Ground Fault FuseThe GT Inverter is equipped with a 600 volt, 1 amp ground fault protection fuse (replace with

Página 23 - Mounting the Inverter

Xantrex Grid Tie Solar InverterOwner’s Manual

Página 24 - 1/2) from

Wiring the Inverter3–4 975-0320-01-01Wiring RequirementsThe AC and DC terminal blocks in the GT Inverter accept wire sizes from #14 AWG to #6 AWG. Und

Página 25 - Surfaces for Mounting

Accessing the Wiring Terminals975-0320-01-01 3–5Accessing the Wiring TerminalsYou must remove the GT Inverter wiring box cover to access the terminal

Página 26 - Figure 2-3

Wiring the Inverter3–6 975-0320-01-01Figure 3-4Insulating Barrier LocationFigure 3-5AC and DC Terminal Block LocationLift bottom edge of barrier to ac

Página 27 - Wiring the Inverter

Connecting the DC Wiring975-0320-01-01 3–7Connecting the DC WiringThe following procedure is illustrated in Figure 3-7. If there is more than one PV s

Página 28 - Important:

Wiring the Inverter3–8 975-0320-01-01Figure 3-7DC Connections for Multiple PV StringsImportant:Depending upon installation and local codes, fusing and

Página 29 - Ground Fault Fuse

Connecting the DC Wiring975-0320-01-01 3–9DC Wiring for Multiple InvertersFor installations with multiple GT Inverters, separate solar arrays are requ

Página 30 - Wiring Requirements

Wiring the Inverter3–10 975-0320-01-01Connecting the AC WiringThe GT Inverter can be connected to a single bi-directional meter, or to dual meters, wh

Página 31

DC and AC Wiring for Multiple Inverters975-0320-01-01 3–11DC and AC Wiring for Multiple InvertersDC and AC wiring for multiple inverters is illustrate

Página 32 - (PV+)(PV-)

Wiring the Inverter3–12 975-0320-01-01Communications Wiring for Multiple InvertersCommunications wiring between multiple GT Inverters allows informati

Página 33 - Connecting the DC Wiring

Communications Wiring for Multiple Inverters975-0320-01-01 3–13Terminators The male network terminator supplied with each GT Inverter (Figure 3-12) is

Página 34

About XantrexXantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to

Página 35 - Grounding not shown

Wiring the Inverter3–14 975-0320-01-01Purchasing Network ComponentsConsult your system designer to determine what network components will be needed fo

Página 36 - Connecting the AC Wiring

Communications Wiring for Multiple Inverters975-0320-01-01 3–15Guidelines for Routing the Network CablesConnecting Network Cable Between Multiple Inve

Página 37 - 975-0320-01-01 3–11

Wiring the Inverter3–16 975-0320-01-01RS-232 cable requirementsTo connect your computer to the GT Inverter, you must use a serial DB9 “straight throug

Página 38 - Xanbus Network Technology

4Starting the InverterChapter 4 contains information on starting up the Xantrex Grid Tie Solar Inverter and performing a functional test.The topics in

Página 39 - Cabling Requirements

Starting the Inverter4–2 975-0320-01-01Checking the PV Array DC VoltageTo check the PV array DC voltage:1. Uncover the PV arrays and expose them to fu

Página 40 - Purchasing Network Components

Commissioning Multiple Inverters975-0320-01-01 4–3Starting up the GT InverterTo start up the inverter:1. Switch the DC/AC disconnect switch to the ON

Página 41

Starting the Inverter4–4 975-0320-01-01If the inverter stops operating after the input current has risen above 1 A, turn the unit off, remove DC power

Página 42

Disconnect Test975-0320-01-01 4–5Disconnect TestThe disconnect test is designed to verify correct operation of the GT Inverter both on initial operati

Página 44

5Monitoring the InverterChapter 5 contains information for understanding the LCD screens and the LED indicators.Monitoring the Front Panel DisplayDuri

Página 45 - Starting up the GT Inverter

975-0320-01-01 iiiAbout This ManualThe purpose of this Owner’s Manual is to provide explanations and procedures for installing, operating, maintaining

Página 46 - 4–4 975-0320-01-01

Monitoring the Inverter5–2 975-0320-01-01Viewing more informationAdditional screens of information about the performance of the GT Inverter can be dis

Página 47 - Disconnect Test

Front Panel Display Screens and What They Mean975-0320-01-01 5–3The protection timer begins counting down the reconnect delay during startup and the “

Página 48

Monitoring the Inverter5–4 975-0320-01-01Normal Operation ModeThe LCD on the GT Inverter is refreshed every two seconds, so all readings are current t

Página 49 - Inverter

Front Panel Display Screens and What They Mean975-0320-01-01 5–5Additional screens for multiple unitsIn addition to the normal system message screens,

Página 50 - Startup Mode

Monitoring the Inverter5–6 975-0320-01-01Offline ModeOffline default displayAt night and when no power is being produced by the PV array (offline mode

Página 51 - Table 5-1

Front Panel Display Screens and What They Mean975-0320-01-01 5–7Table 5-7Additional Offline Mode Screens for Each GT Inverter Unit in a Multiple Unit

Página 52 - Normal Operation Mode

Monitoring the Inverter5–8 975-0320-01-01Fault ModeWhen a fault state is detected, the appropriate fault message appears on the front panel display at

Página 53

Front Panel Display Screens and What They Mean975-0320-01-01 5–9Additional Fault messages for all systemsAdditional message screens can be viewed in f

Página 54 - Offline Mode

Monitoring the Inverter5–10 975-0320-01-01Special ScreensSpecial message screens are displayed in specific situations that are not considered fault si

Página 55 - Multiple Unit System

Status Indicator Lights975-0320-01-01 5–11Status Indicator LightsThe GT Inverter has two status indicator lights (LEDs) located below the front panel

Página 56 - Fault Mode

About This Manualiv 975-0320-01-01Conventions UsedThe following conventions are used in this guide.Abbreviations and AcronymsWARNINGWarnings identify

Página 58 - Custom Screens

6Maintenance and TroubleshootingChapter 6 contains information about how to provide general maintenance for the Xantrex Grid Tie Solar Inverter. It al

Página 59

Maintenance and Troubleshooting6–2 975-0320-01-01Angle of the sun The angle of the sun in relation to the PV array surface—the array orientation—can d

Página 60

Performing General Maintenance975-0320-01-01 6–3Performing General MaintenanceFollow these simple routines to ensure many years of service and optimal

Página 61 - Troubleshooting

Maintenance and Troubleshooting6–4 975-0320-01-01Replacing the Ground Fault Protection FuseThe ground fault protection fuse will blow when severe leak

Página 62 - Other Factors

Replacing Parts975-0320-01-01 6–5Figure 6-1Location of Fuse, Front Panel Cover RemovedFigure 6-2Display Front Panel AssemblyGround Fault Protection Fu

Página 63 - Replacing Parts

Maintenance and Troubleshooting6–6 975-0320-01-01Replacing the InverterIf your GT Inverter requires servicing, you can replace it with another inverte

Página 64

Replacing Parts975-0320-01-01 6–73. Using an insulated screwdriver, disconnect the PV NEGATIVE (–) wire from the terminal block inside the inverter. C

Página 65 - Display Front Panel Assembly

Maintenance and Troubleshooting6–8 975-0320-01-01To replace the inverter on the wiring box:1. If it has not already been removed, remove the display f

Página 66 - Replacing the Inverter

Identifying Error/Fault Conditions and Solutions975-0320-01-01 6–9Identifying Error/Fault Conditions and SolutionsMost error or fault conditions will

Página 67 - 975-0320-01-01 6–7

About This Manual975-0320-01-01 vSymbols UsedRelated InformationYou can find more information about Xantrex Technology Inc. as well as its products an

Página 69

ASpecificationsAppendix A contains information about the specifications of the Xantrex Grid Tie Solar Inverter.The topics in this appendix are organiz

Página 70

SpecificationsA–2 975-0320-01-01Electrical SpecificationsInputOutputInput voltage, Maximum Power Point range 240 to 550 VdcAbsolute maximum array open

Página 71 - Specifications

Output Power Versus Ambient Temperature975-0320-01-01 A–3Adjustable Voltage, Frequency and Reconnection SettingsUtility disconnect settings can be adj

Página 72 - Electrical Specifications

SpecificationsA–4 975-0320-01-01EfficiencyEnvironmental SpecificationsUser DisplayMaximum efficiency 96.2%CEC efficiency 95.5%Night-time tare loss 1 W

Página 73 - Output Power (W)

Mechanical Specifications975-0320-01-01 A–5Display AccuracyMechanical SpecificationsRegulatory ApprovalsThe GT Inverter has complete on-board over-cur

Página 75 - Regulatory Approvals

975-0320-01-01 WA–1Warranty and Return InformationWarrantyWhat does this warranty cover? This Limited Warranty is provided by Xantrex Technology Inc.

Página 76

Warranty and ReturnWA–2 975-0320-01-01What does this warranty not cover? This Limited Warranty does not cover normal wear and tear of the product or c

Página 77 - Warranty

Warranty and Return975-0320-01-01 WA–3Return Material Authorization PolicyBefore returning a product directly to Xantrex you must obtain a Return Mate

Página 79 - Out of Warranty Service

Warranty and ReturnWA–4 975-0320-01-01Information About Your SystemAs soon as you open your Xantrex Grid Tie Solar Inverter package, record the follow

Página 80 - Information About Your System

975-0320-01-01 IX-1Aabbreviations and acronyms ivAC circuit breaker requirements 3–4AC grounding requirements 3–1AC output voltage ratings A–2AC wirin

Página 81

IndexIX–2 975-0320-01-01configuration 2–1messages in normal operation 5–5messages in offline mode 5–6Ooperationfactors affecting performance 6–1invert

Página 83

Xantrex Technology Inc.1 800 670 0707 Tel toll free NA1 360 925 5097 Tel direct1 360 925 5143 Fax [email protected]

Página 84 - Printed in China

975-0320-01-01 viiImportant Safety InstructionsSAVE THESE INSTRUCTIONS—This manual contains important instructions that shall be followed during the i

Comentários a estes Manuais

Sem comentários